Resources
Dimming and controls.
Every Elium fixture dims to 1% as standard. Choose the driver for the control system on the job, then check the wall dimmer against the list Elium has tested.
Step 1
Choose the driver.
The driver code is part of the housing or frame number. The builder on each product page offers only the drivers that family takes.
| Code | Driver | Dims to | Use with | Families |
|---|---|---|---|---|
| X | Standard 0-10V, TRIAC, ELV | 1% | Wall dimmers below, or any 0-10V control | Residential, Canless, Commercial, Double Head Canless, Double Head Commercial, Downsizer Ring, Commercial Downsizer Ring |
| TE | 120V phase TRIAC, ELV | 5% | 120V wall dimmers | Canless, Double Head Canless |
| ED | eldoLED 0-10V 0-10V | 0.1% | Hospitality and theatrical dimming on 0-10V controls | Residential, Canless, Commercial, Double Head Canless, Double Head Commercial, Commercial Downsizer Ring |
| AL | eldoLED DALI-2 DALI-2 | 0.1% | Addressable: each fixture on the DALI bus, no wall dimmer | Residential, Canless, Commercial, Double Head Canless, Double Head Commercial, Commercial Downsizer Ring |
| LN | Lutron Athena node Lutron Athena | 0.1% | Lutron Athena systems, programmed by the controls contractor | Residential, Commercial, Double Head Commercial, Commercial Downsizer Ring |
| TW | Tunable White Two-channel 0-10V | 1% | One 0-10V control for intensity, one for color temperature | Tunable White |
| BT | Tunable White DALI-2 eldoLED DALI-2 | 0.1% | Intensity and color on the DALI bus | Tunable White |
Step 2
Check the wall dimmer.
120V TRIAC / ELV wall dimmers
With the standard driver (code X). Every trim series, 2″, 3″ and 4″.
| Manufacturer | Model | Dimming range |
|---|---|---|
| Leviton | IPE04 | 1%–100% |
| Leviton | 6673-10W | 1%–100% |
| Leviton | VP106 | 1%–100% |
| Leviton | 6161 | 1%–100% |
| Leviton | 6674 | 1%–100% |
| Lutron | RRD-6CL | 1%–100% |
| Lutron | DVCL-153P | 1%–100% |
| Lutron | TGCL-153P | 1%–100% |
| Lutron | DVELV-303P | 1%–100% |
| Lutron | TG-600P | 1%–100% |
| Lutron | CT103P | 1%–100% |
| Lutron | MAELV600 | 1%–100% |
| Lutron | FAELV500 | 1%–100% |
| Lutron | S-600P | 1%–100% |
| Lutron | SCL-153P | 1%–100% |
| Lutron | PD-6WCL | 1%–100% |
| Lutron | DVLV-600P | 5%–100% |
| Lutron | DV-603P | 1%–100% |
| Lutron | MA-PRO | 1%–100% |
| Lutron | MACL-153M | 1%–100% |
| Eaton | TAL06P1-C1 | 1%–100% |
| Cooper | SLC03P / DAL06P | 1%–100% |
| Cooper | DLC03P | 1%–100% |
| Cooper | RI061-VW-K2 | 1%–100% |
| Cooper | AAL06A-C2 | 1%–100% |
| Lightolier | ZP260QEW | 1%–100% |
0-10V wall dimmers, 120/277V
With the standard driver (code X) or eldoLED 0-10V (code ED).
| Manufacturer | Model | Dimming range |
|---|---|---|
| Lutron | NFTV | 1%–100% |
| Lutron | DVSTV | 1%–100% |
| Lutron | DVTV | 1%–100% |
| Leviton | IP710-DL | 1%–100% |
0-10V wall dimmers for Tunable White
Two dimmers per fixture: one for intensity, one for color.
| Manufacturer | Model | Dimming range |
|---|---|---|
| Lutron | NFTV | 1%–100% |
| Lutron | DVSTV | 1%–100% |
| Lutron | DVTV | 1%–100% |
| Leviton | IP710-DL | 1%–100% |
No tested dimmer matches that search. Ask your Elium agent before specifying an untested dimmer.
Dimmer compatibility chart for reference only. Testing conducted by Elium Lighting is not a substitute for and does not imply certification by an independent laboratory or any other standards certification. Refer to manufacturer specifications for more detailed information on product certifications and standards. Consult the dimmer manufacturer prior to installation to ensure compatibility.
System control
DALI-2 and Lutron Athena.
With a DALI-2 driver (AL, or BT for Tunable White) each fixture is addressed on the DALI bus, and with the Lutron Athena node (LN) the fixture joins an Athena system. Neither uses a wall dimmer: dimming to 0.1% is set up and programmed by the controls contractor. Lutron Athena is not offered on Canless or Double Head Canless.
Specifying controls on a project?
Your Elium agent can confirm a dimmer or control system before it goes on the schedule.