Guided selection

Find a product.

Pick as many as you like in any row — results match every row you have used. Hover or tap any option for what it means and where it is used.

Downlight size to scale

In the ceiling

Beam angle

Color temperature lower is warmer

Output

Dimming

Dims down to

Heads

Application

Installation

What do these options mean?

Downlight size

2″
The smallest downlight in the line — near-invisible in the ceiling plane. The lit opening and the beam angles are the same at every size — they all take the same module. Tilt goes to 35°.
3″
The workhorse size. Discreet, with serious output behind it. The lit opening and the beam angles are the same at every size — they all take the same module. Tilt goes to 35°.
4″
The classic size, with maximum adjustability across the range. The lit opening and the beam angles are the same at every size — they all take the same module. Tilt goes to 40°.

In the ceiling

Housing New Construction rough-in
A metal housing is nailed to the joists before the ceiling goes up, and the module and trim go in later. The usual choice when the ceiling is open.
Canless No housing, shallow plenum
No housing at all: the fixture clips into a cut hole and the junction box sits beside it. Fits where the space above the ceiling is too shallow for a can.
Downsizer™ Into an existing housing
Drops the visible opening of a can that is already in the ceiling — a 6″ hole becomes a 3″ one — working from below, with drywall patching to close the gap.

Beam angle

15° Spot
Aim one at a painting, a sculpture or a stone feature. Tight enough that the object is lit and the wall around it is not. About 2.1 ft across, 8 ft below the fixture.
24° Narrow flood
The grazing angle for a feature wall, a headboard or joinery — wide enough to cover the surface, narrow enough to keep the light off the floor. About 3.4 ft across, 8 ft below the fixture.
36° Flood
The default for general light in a room. On a normal ceiling a row of these overlaps into even light without hot spots underneath. About 5.2 ft across, 8 ft below the fixture.
50° Wide flood
For low ceilings and corridors, where fixtures are close to what they are lighting and a narrower beam would read as a line of bright pools. About 7.5 ft across, 8 ft below the fixture.

Color temperature

2400K Warmest
Candlelight territory. Used where the light itself is meant to feel like a flame — bars, restaurants, a warm residential scheme.
2700K Warm
What a traditional incandescent lamp looked like. The safe residential default in most of North America.
3000K Soft
Slightly crisper than 2700K and still warm. The most specified residential and hospitality color.
3500K Neutral
Reads clean rather than warm or cool. Common in kitchens, offices and retail where materials need to look accurate.
4000K Cool
Neutral-to-cool white. Workspaces, galleries, garages — anywhere alertness matters more than warmth.
Dim to warm Warms as it dims
One fixed color that gets warmer as it dims, the way a filament lamp does. Built on the 1,250 and 1,500 lm packages.
Tunable Full range
The color is set by the control system, anywhere from 1800K to 6500K, and can change through the day. Tunable White family only.

Output

Under 1,000 lm
Accent, cove and low-ceiling work
1,000 – 2,000 lm
General residential downlighting
2,000 – 3,500 lm
High ceilings and spec-grade projects
3,500 lm +
Maximum output, two-head fixtures

Dimming

0-10V Wired control
A separate pair of control wires runs to the fixture. The standard way to dim a commercial project, and what most architectural control systems expect.
TRIAC / ELV Standard wall dimmer
Dimmed on the line voltage itself, so an ordinary wall dimmer works and no control wiring is needed. The usual residential choice.
DALI-2 Addressable
A digital bus: every fixture has an address and can be re-grouped in software rather than by rewiring.
Lutron Athena node
Driver built for the Lutron Athena system, with the node integral to the fixture, so it commissions as a Lutron device rather than as a generic 0-10V load.

Dims down to

to 1% Standard
Standard across the range. At 1% the room reads dim but the fixture is still clearly on.
to 0.1% Hospitality, theatrical
Ten times deeper. Worth specifying where the light has to disappear smoothly — hotel rooms, screening rooms, restaurants late in the evening.
to 5% TRIAC only
The floor of the 120V TRIAC/ELV driver. Fine for general light; not deep enough for a scene that has to fade to almost nothing.

Heads

One head A single aimed light
One module behind one opening — the usual downlight.
Two heads Two aimed lights, one frame
Two independently aimed modules in a single frame, each with its own opening, so one fixture lights two things — a picture and the floor below it, say.

Application

Residential
Everything specified for a house — new construction, remodel and retrofit, at residential output.
Commercial
Higher output, shallow plenum depth and non-IC options for spec-grade projects.

Installation

New Construction Ceiling still open
The ceiling is not up yet, so a housing can be fixed to the structure and wired in the open.
Remodel Ceiling closed, no fixture there
The ceiling is finished but there is no fixture in that spot yet. A hole is cut and the fixture clips in from below.
Retrofit A fixture is already there
Something is already installed in that hole. The existing can stays where it is and the Elium ring and module go into it.
22 products
2″
New construction

2″ Residential

Up to 2,000 lm IC Airtight / R60 / Plenum Rated
3″
New construction

3″ Residential

Up to 2,000 lm IC Airtight / R60 / Plenum Rated
4″
New construction

4″ Residential

Up to 2,000 lm IC Airtight / R60 / Plenum Rated
2″
Residential

2″ Canless

Up to 950 lm IC rated
3″
Residential

3″ Canless

Up to 950 lm IC rated
4″
Residential

4″ Canless

Up to 950 lm IC rated
2″
Commercial

2″ Commercial

Up to 3,500 lm IC 1,500 lm / Non-IC 3,500 lm
3″
Commercial

3″ Commercial

Up to 3,500 lm IC 1,500 lm / Non-IC 3,500 lm
4″
Commercial

4″ Commercial

Up to 3,500 lm IC 1,500 lm / Non-IC 3,500 lm
3″
Tunable

3″ Tunable White

Up to 1,250 lm IC Airtight / R60 / Plenum Rated
4″
Tunable

4″ Tunable White

Up to 1,250 lm IC Airtight / R60 / Plenum Rated
2″
Double head · Residential

2″ Double Head Canless

1,900 lm total IC to 950 lm per head
3″
Double head · Residential

3″ Double Head Canless

1,900 lm total IC to 950 lm per head
4″
Double head · Residential

4″ Double Head Canless

1,900 lm total IC to 950 lm per head
2″
Double head · Commercial

2″ Double Head Commercial

Up to 7,000 lm IC 3,000 lm / Non-IC 7,000 lm
3″
Double head · Commercial

3″ Double Head Commercial

Up to 7,000 lm IC 3,000 lm / Non-IC 7,000 lm
4″
Double head · Commercial

4″ Double Head Commercial

Up to 7,000 lm IC 3,000 lm / Non-IC 7,000 lm
2″
Downsizer · Residential

2″ Downsizer™ Ring

1,000 lm Existing 3″, 4″, 5″, 6″ and 8″ housings
3″
Downsizer · Residential

3″ Downsizer™ Ring

1,000 lm Existing 4″, 5″, 6″ and 8″ housings
4″
Downsizer · Residential

4″ Downsizer™ Ring

1,000 lm Existing 5″, 6″ and 8″ housings
3″
Downsizer · Commercial

3″ Commercial Downsizer™ Ring

Up to 2,500 lm Existing 4″, 5″, 6″, 7″ and 8″ frames
4″
Downsizer · Commercial

4″ Commercial Downsizer™ Ring

Up to 2,500 lm Existing 5″, 6″, 7″ and 8″ frames

Round or square: every product takes both, so shape is not a filter here. Nearly every product is also offered flanged or flangeless — the 2″ Commercial families are flanged only and the Downsizer Rings flangeless only. Choose the trim on the product page.
Voltage is the same: every product is available with a universal 120–277V driver, and the canless families add a 120V-only TRIAC driver — so any of them will run on a 120V circuit. The driver is part of the catalog number, chosen on the product page.

Not finding the fixture the drawing calls for?

Send us the detail and an agent will work it through with you.